ITEM DETAILS
Mileage
VIN
36’' Length, 68,000 lb. GVWR, Thermo King Precedent S-600 Refrigeration Unit, Diesel Powered, Shore Power, Sliding Tandems, Air Suspension, Lift Gate, 295/75R22.5 Tires

***It has been reported that the asset will be de-identified/wrapped prior to pick-up***

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Serial Number / VIN Click here to open photos and videos of this item.  
Motor Vehicle Safety Standards Label Yes Click here to open photos and videos of this item.  
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
(2)


Refrigeration Unit
Description Rating Details  
Control Panel Operational Click here to open photos and videos of this item.  
Refrigeration Unit Hours 11,640 Total Hours; 7,272 Engine Run Hours Click here to open photos and videos of this item.  
Make and Model Make: Thermo King; Model: TK488CR
Emission Certification Label US EPA certification label Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check - Reefer The unit could not be operationally checked. Would not start after trying to jump start the item.
(7)


Air System
Description Rating Details  
Air Valve Click here to open photos and videos of this item.  
Air Tank Click here to open photos and videos of this item.  
Air Lines Click here to open photos and videos of this item.  
Air Cylinders Click here to open photos and videos of this item.  
Limited Function Check The air system was not operationally checked.
(4)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Frame Rails/ Main Beams Condition Click here to open photos and videos of this item.  
Axle Condition Click here to open photos and videos of this item.  
Springs/Hangers Condition Click here to open photos and videos of this item.  
Suspension Air Bags Click here to open photos and videos of this item.  
Brake Lines/Hoses Not operationally checked
Limited Function Check - Brakes The brakes were not operationally checked.
Tire Condition Click here to open photos and videos of this item.  
Tires Left front outer: 7/32"; Left front inner: 7/32"; Left rear outer: 5/32"; Left rear inner: 4/32"; Right rear outer: 7/32"; Right rear inner: 5/32"; Right front outer: 7/32"; Right front inner: 7/32"
Wheel Condition
Wheel Studs
Power Receptacle Functional Not operationally checked Click here to open photos and videos of this item.  
Lights/Wiring Condition Not operationally checked
Marker Lights Functional Not operationally checked Click here to open photos and videos of this item.  
Brake Lights Functional Not operationally checked Click here to open photos and videos of this item.  
License Plate Light Functional Not operationally checked Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Click here to open photos and videos of this item.  
Deck/ Floor Condition Ramp seen in photographs will be removed prior to sale. Click here to open photos and videos of this item.  
(21)
 

Oil Sample Analysis
  engine
date of analysis Dec 02, 2019
Silicon 11.9 PPM
Tin 0 PPM
Silver 0 PPM
Aluminum 5.48 PPM
Chromium 0.11 PPM
Lead 0 PPM
Copper 0.47 PPM
Nickel 0.44 PPM
Iron 7.68 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.